EL-Esthetic Line,dental implants,dentures
EL-Esthetic Line,dental implants,dentures

  • Accordion EL ENG

    EL / Esthetic Line

    EL-Esthetic Line,dental implants,denturesThe Esthetic Line implant is a conical shaped implant offering surgical and prosthetic compatibility to the BL line of implants. The EL implant’s core is the same as that of the BL implant and thus follows the same insertion protocol in soft bone. The EL implant is endowed with generous apical threading which provides superb primary stability, especially in soft bone.

    • Read more »

      The prosthetic connection of the EL implant is the same as the BL; a Morse taper locking connection which delivers an added level of security against abutment loosening, micro movements and other issues that are a result of implant connection gaps.

      The platform switching, Concave Esthetic Concept dental prosthetic system of the EL implant system offers a large range of options as well as tissue shaping possibilities. Despite the large range of prosthetic freedom, the system remains uncomplicated and easy to use due to the fact that the prosthetic connection is the same for all implant diameters.

    ND / Narrow Diameter Implant

    ND Line,dental implants,denturesThe Narrow Diameter dental implant is a two piece slender bodied implant with a platform diameter of only 3mm. This implant is ideal for limited and narrow crestal spaces in the anterior region. Generous threading on the implant body, culminating in sharper threads at the apex deliver stability as well as ease of insertion.

    • Read more »

      A simplified surgical protocol in combination with the conservative dimensions of this dental implant facilitate the resolution of dental implant cases which would have otherwise required the use bone augmentation and higher treatment costs.

    GL / Livello Gengivale

    GL Line,dental implants,denturesThe Gingival Level dental implant is a conical shaped implant with an internal hex connection. The implant is endowed with a micro grooved collar for cortical maintenance and crowned with a polished rim to accommodate soft tissues.

    • Read more »

      This dental implant benefits from an internal hex convex platform that provides an ideal seal when joined to the GL abutments which in turn have a concave shaped platform. Implants of the GL range have the same platform dimensions despite differing diameters and thus allow for a simplified prosthetic protocol.

    • 1Convex platform

      The convex implant platform, in conjunction with the concavity of the implant’s base form a “suction cup” fit, once the abutment is tightened into final seating.

    • 2Polished gingival collar

      Extending down for one millimeter down from the top of the implant platform, the polished surface is ideal for accommodating the gingival tissue.

    • 3Micro-threading

      The micro threads increase functional surfaces, adapting them to the compact cortical bone tissue and safeguard it against aggression from larger threads to be found in conventional implants. The micro-threads are essential to the maintenance of cortical bone height around the implant.

    • 4Single internal hex connection

      The complete GL family is endowed with a single connection. Independent of the implant diameter, one abutment fits all. Thus reducing system complexity and cost.

    • 5Double helix threading

      The double-helix design sets c-tech Implants apart from the single helix implants by giving them a more symmetrical introduction into the bone. This translates into masticatory load balance which drastically reduces stress. Its symmetry also renders the implant self-centering, eliminating any form of misalignment in terms of the main axis of the osteotomy site. The pitch of the threads allows for an insertion time that is reduced by half.

    • 6Rounded apex

      Protection of the sinus floor, nerve canal and other important anatomical structures during insertion

    • Passivated surface

      The implant surface is blasted with aluminum oxide and then subjected to progressive etching using citric acid.
      This surface treatment accelerates the osseointegration process by providing a greater and more uniform area of contact between bone and implant while favoring an immediate implant load. The treatment provides for a uniform surface with progressive trabeculation to be achieved. An additional advantage of the citric acid treatment is that it leaves no traces following decontamination, further reducing the risk of implant failure.

    MB / Monoblock

    MB Line,dental implants,denturesThe Mono Block is a one piece implant with a diameter of 3mm. The system offers 2 prosthetic options; O-ball head for removable full prosthesis as well as tapered abutment for crown and bridge applications.

    • Read more »

      To better accommadate the differing soft tissue and bone requirements that are encountered in the upper and lower jaw, the system is endowed with 2 main body profiles.

    • 1Prosthetic Options

      Choice between square or O-ball head depending on fixed or removable applications.

    • 2Support for Fixed Recontructions

      A tapered head with a 4,8mm height above the 3,1mm platform offers and optimal base and structure for the fixed reconstruction.

    • 3Gingival Collar

      MAN-OB/MAN-TAP smooth collar provides the platform switching height to accommodate the average mandibular gingival tissue.

    • 4Mandibular Cortical Maintenance

      Augmented MAN-OB/MAN-TAP micro grooving for the increased cortical height of the mandibular bone.

    • 5Low Profile Threading

      Low profile threading offers surface area yet with the reduced resistance necessary for placement in the D1/D2 bone that can be encountered in the mandible.

    • 6Surface Topography

      Blasted and acid etched main body surface.

    • 7Mandibular Apex

      Sharp apex to facilitate advancement in D1/D2 bone.

    • 8Augmented Gingival Collar

      MAX-OB/MAX-TAP smooth collar platform switching fits the thicker maxillary gingival tissue

    • 9Maxilla Type Bone Micro Grooving

      MAX-OB/MAX-TAP micro grooving accommodates the thinner cortical bone that is encountered in the maxilla.

    • 10Aggressive Main Body Threading

      MAX-OB/MAX-TAP main body threading, agressive reverse buttress threads deliver the surface area and stability required by softer maxillary bone

    • 11Maxilla Type Apex

      Rounded tip is ideal for the maxilla so as to prevent the possible perforation of the sinus.

    • System Compatiblity

      Choice of tapered and O-ball head prosthetics.
      O-ball head is compatible with SD, GL, BL and EL O-ball attachments

    SD / Small Diameter Implants

    SD Line,dental implants,denturesThe Small Diameter dental implant system is a family of one piece implants with varying diameters of 1.8mm, 2.1mm, 2.4mm and 2.5mm. The options for each diameter of aggressive thread, fine thread, collar and non-collar, O-ball head and square head; make the range one of the largest mini dental implant ranges on the market.

    • Read more »

      This system is ideal for the practitioner who is looking for minimally invasive solutions for stabilizing over-dentures, limited spaces and bone volumes as well as treatment cost constraints

    • 1Prosthetic choice

      Choice between square or o-ball head depending on fixed or removable applications.

    • 2Micro grooving

      The lower aspect of the implant collar is endowed with micro grooves to help maintain cortical bone.

    • 3Fine threading

      The fine thread SD implants are designed to facilitate the placement in hard bone.

    • 4Passivated surface

      The implant surface is blasted with aluminum oxide and then subjected to progressive etching using citric acid. This surface treatment accelerates the osteointegration process by providing a greater and more uniform area of contact between bone and implant while favoring an immediate implant load.

    • 5Smooth collar

      The top aspect of every collared implant is smooth so as to better accommodate soft tissue.

    • 6Aggressive threading

      The aggressive thread for SD Implants are designed for the added compression and surface area required in soft bone placement.

    • 7Collared and non-collared models

      C-tech provides SD models with and without gingival collars, allowing the practitioner to better address cases with differing gingival thicknesses.

    • Implant body

      The anatomically shaped implants are produced from medical grade 5 titanium.

Dental Implants

Diameter ø 3.8
ø 3.8/8 mm EL-3508
ø 3.8/9 mm EL-3509
ø 3.8/11 mm EL-3511
ø 3.8/13 mm EL-3513
ø 3.8/15 mm EL-3515
Diameter ø 4.3
ø 4.3/9 mm EL-4309
ø 4.3/11 mm EL-4311
ø 4.3/13 mm EL-4313
ø 4.3/15 mm EL-4315
Diameter ø 5.1
ø 5.1/9 mm EL-5109
ø 5.1/11 mm EL-5111
ø 5.1/13 mm EL-5113
ø 5.1/15 mm EL-5115
Diameter ø 6
ø 6/8 mm EL-6008
ø 6/10 mm EL-6010
ø 6/12 mm EL-6012
ø 6/14 mm EL-6014
Diameter ø 7
ø 7/8 mm EL-7008
ø 7/10 mm EL-7010
ø 7/12 mm EL-7012
ø 7/14 mm EL-7014

EL Short Implant

Height 7mm
ø 4,3/7 mm EL-4307
ø 5,1/7 mm EL-5107
ø 6/7 mm EL-6007
ø 7/7 mm EL-7007

Video

C-TECH - Video Concetti Protesici

C-TECH - Video Concetti Protesici

EL Esthetic Line Implant - New Video

EL Esthetic Line Implant

Purity and precision

Material purity and surface treatment

Material purity starts with the acquisition of raw material from only the most reliable sources of which each lot is accompanied by its own material certificate and is completely traceable at all phases of production and later use. The production facility in which all the implants and components are made is owned and operated by C-TECH and is certified to the highest standards governing the production of dental/medical devices. To maintain these standards, regular and independent audits are performed by the German auditor, TUV Süd. All up to date certificates are available for download on the company website.

The machining of the EL implant is an intricate process due to the precision required for the Morse conical connection and the exterior complexity of the implant. This intricacy requires double the machining time that would be necessary for that of an average implant. Throughout and following each step of the production process, the implants are thoroughly cleaned in 5 seperate cleaning stages, consisting of a total of 20 cleaning cycles. This attention to cleanliness is in order to assure that no risk of any production residue is remaining on the implant surface.

The surface topography is created through a patented acid etching process. The adjacent photos made with a scanning electron microscope (SEM) demonstrate the lack of impurities on the implant surface as well the abundant surface area created through the patented acidification process.

The purity of the grade 4 titanium used for the EL implant and the surface topology were independently verified through an investigation carried out with a scanning electron microscope (SEM) by the University of Cologne and Medical Material Research Center of Berlin, Germany. The investigation demonstrated the highest level of purity and cleanliness resulting in the award of the BDIZ quality seal. This investigation is avaliable in its long form on the C-TECH website.

Precision components

The successful achievement of a Morse lock and cold weld seal in the implant-prosthetic connection depends on high precision machining. A perfect Morse connection will result in a structural integrity and strength that will be as if the 2 parts were fused together and thus will practically eliminate the gap between the implant and the abutment. Accordingly, the C-TECH components are machined to a tolerance of within 10 microns.

This mechanical fusion of the prosthetic part and the implant has 2 important benefits; prevention of the bacterial colonization of the gap, which can lead to bone loss around the implant, as well as the elimination of micro-movements between the implant and abutment and the consequent screw loosening which can lead to prosthetic failure. The SEM photos on the right show different magnifications of the tight abutment and implant connection. The final photo at the bottom, at 1000 X magnification, shows a fine line where the abutment and the implant meet. This practically nonexistent gap is less than the 1,5 microns width of the bacteria to be found in the oral cavity.