DZZ | Deutsche Zahnärztliche Zeitschrift – Settembre 2015 – Stabilizzazione di protesi dentali parziali rimovibili usando mini-impianti – 2 case report

DZZ | Deutsche Zahnärztliche Zeitschrift • Settembre 2015

Stabilizzazione di protesi dentali parziali rimovibili usando mini-impianti – 2 case report

Prof. Dr. Torsten Mundt Center for Dental, Oral and Maxillofacial Surgery Greifswald
Polyclinic for dental prosthetics and materials science
University Medical Center, Christian Lucas, Reiner Biffar University of Greifswald · Department of Prosthodontics, Geriatric Dentistry and Medical Materials Science, Friedhelm Heinemann University of Greifswald · Department of Prosthodontics, Geriatric Dentistry and Medical Materials Science

Perché leggere questo articolo?
Questo case report è una guida che illustra come è possibile usare i mini-impianti come monconi strategici per la stabilizzazione di protesi dentali parziali rimovibili e per il sostegno dei denti rimanenti.

Introduzione: L’utilizzo di impianti dentali convenzionali come monconi strategici per le protesi dentali parziali rimovibili è costoso e richiede una larghezza sufficiente della cresta alveolare. I mini-impianti dentali monopezzo (< 2,8 mm) forniscono un’opzione di trattamento alternativa per questa indicazione.

Metodo di trattamento: Uno schema terapeutico per mini-impianti dentali strategici (MDI, 3M ESPE Dental GmbH, Seefeld, Germania) include 3 monconi (denti + impianti) per quadrante mascellare e 2 monconi per quadrante mandibolare.

Risultati: Nel primo case report, una paziente ha perso uno dei 2 monconi della corona conica del canino dell’arcata inferiore. Di conseguenza sono stati inseriti 2 mini-impianti dentali con stabilità primaria sufficiente (coppia d’inserimento > 35 Ncm) che sono stati caricati immediatamente con le matrici utilizzando la polimerizzazione intraorale.
La seconda paziente aveva 2 molari rimasti. Dopo il posizionamento di 4 mini-impianti dentali (coppia d’inserimento 20-25 Ncm), la protesi dentale parziale rimovibile, che è supportata dalle corone coniche, è stata ribasata usando un materiale morbido. Quattro mesi dopo, le matrici sono state polimerizzate nella protesi presso il laboratorio odontoiatrico tramite impronta.

Conclusione: I monconi strategici supplementari che usano mini-impianti dentali richiedono di seguire le raccomandazioni relativamente al numero e alla posizione dei mini-impianti dentali, all’approccio di carico, alla conoscenza anatomica, all’esperienza chirurgica soprattutto nel trattamento della mandibola, e un’esperienza protesica sufficiente.


 

References

1. Ellis JS, Levine A, Bedos C et al.: Refusal of implant supported mandibular overdentures by elderly patients. Gerodontology 2011;28:62–68

2. Elsyad MA, Gebreel AA, Fouad MM, Elshoukouki AH: The clinical and radiographic outcome of immediately loaded mini implants supporting a mandibular overdenture. A 3-year prospective study. J Oral Rehabil 2011;38:827–834

3. Elsyad MA, Ghoneem NE, El-Sharkawy H: Marginal bone loss around unsplinted mini-implants supporting maxillary overdentures: a preliminary comparative study between partial and full palatal coverage. Quintessence Int 2013;44:45–52

4. Esposito M, Grusovin MG, Maghaireh H, Worthington HV: Interventions for replacing missing teeth: different times for loading dental implants. Cochrane Database Syst Rev 2013, Mar 28;3:CD003878. doi:10.1002/14651858.CD003878.pub5. Review

5. Flanagan D, Mascolo A: The mini dental implant in fixed and removable prosthetics: a review. J Oral Implantol 2011;37(Spec No):123–132

6. Fuh LJ, Huang HL, Chen CS et al.: Variations in bone density at dental implant sites in different regions of the jawbone. J Oral Rehabil 2010;37:346–351

7. Griffitts TM, Collins CP, Collins PC: Mini dental implants: an adjunct for retention, stability, and comfort for the edentulous patient. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2005;100:e81–e84

8. Hasan I, Bourauel C, Mundt T, Stark H, Heinemann F: Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature. Biomed Tech 2014;59:1–5

9. Heinemann F, Bourauel C, Hasan I, Mundt T: Mini-Implantate als strategische Pfeiler zur verbesserten Retention von Teilprothesen. Implantol J 2014;18:26–33

10. Huemer P, Huemer B, Gollmitzer I: Mini-Implantate – Möglichkeiten und Grenzen im zahnlosen Unterkiefer. Quintessenz 2013;64:315–325

11. Klein MO, Schiegnitz E, Al-Nawas B: Systematic review on success of narrow-diameter implants. Int J Oral Maxillofac Implant 2014;29:43–54

12. Krennmair G, Krainhöfner M, Waldenberger O, Piehslinger E: Dental implants as strategic supplementary abutments for implant tooth-supported telescopic crown-retained maxillary dentures: a retrospective follow-up study for up to 9 years. Int J Prosthodont 2007;20:617–622

13. Mangano FG, Caprioglio A, Levrini L, Farronato D, Zecca PA, Mangano C: Immediate loading of mandibular overdentures supported by one-piece, direct metal laser sintering mini-implants: A short-term prospective clinical study. J Periodontol. 2014;2:1–13.[Epub ahead of print]

14. Morneburg TR, Pröschel PA: Success rates of microimplants in edentulous patients with residual ridge resorption. Int J Oral Maxillofac Implants 2008;23:270–276

15. Mundt T, Heinemann F, Stark T, Schwahn C, Biffar R: Verlustanalyse von Mini-Implantaten zur Fixierung totaler Prothesen. Dtsch Zahnärztl Z 2014;69:262–270

16. Mundt T, Schwahn C, Stark T, Biffar R: Clinical response of edentulous people treated with mini dental implants in nine dental practices. Gerodontology 2015;32:179–187

17. Preoteasa E, Imre M, Preoteasa CT: A 3-year follow-up study of overdentures retained by mini-dental implants. Int J Oral Maxillofac Implants 2014;29:1170–1176

18. Rammelsberg P, Bernhart G, Lorenzo Bermejo J, Schmitter M, Schwarz S: Prognosis of implants and abutment teeth under combined tooth-implant supported and solely implant supported double-crown-retained removable dental prosthesis. Clin Oral Implants Res 2014;25:813–818

19. Scepanovic M, Calvo-Guirado JL, Markovic A et al.: A 1-year prospective cohort study on mandibular overdentures retained by mini dental implants. Eur J Oral Implantol 2012;5:367–379

20. Shatkin TE, Petrotto CA: Mini dental implants: a retrospective analysis of 5640 implants placed over a 12-year period. Compend Contin Educ Dent 2012;33(Spec 3):2–9

21. Walzer W: Mini-Implantate zur Stabilisierung von Teilprothesen. Dent Implantol 2013;17:396–401

22. Wentaschek S, Scheller H, Schmidtmann I et al: Sensitivity and specificity of stability criteria for immediately loaded splinted maxillary implants. Clin Implant Dent Relat Res 2014, Dec 23. doi:10.1111/cid.12283. [Epub ahead of print]

Pubblicazioni Scientifiche

Caso clinico di riabilitazione totale al mascellare superiore con protocollo di chirurgia guidata e carico immediato

Caso clinico di riabilitazione totale al mascellare superiore con protocollo di chirurgia guidata e carico immediato Dr. Fabio Lo Meo Introduzione Sempre più al giorno d’oggi le moderne tecniche chirurgiche si orientano verso protocolli semplificati e mini invasivi, volti ad offrire ai pazienti trattamenti più efficaci, altamente predicibili e con tempi di trattamento ridotti. Inoltre tale approccio rende i trattamenti meglio tollerati, più veloci, con decorsi postoperatori più confScopri di più

Dentista Michael Weiland: un'ottima cura per me!

Magazine PIP • Practical implantology and implant prosthetics • 08 Giugno 2022 Dentista Michael Weiland: un'ottima cura per me! Fin tempi di carenza di manodopera qualificata e di una fondamentale mancanza di personale, la prima cosa che molti perdono sono i servizi che un tempo erano considerati così essenziali. Ma più un pezzo di hardware è intercambiabile e le battaglie sugli sconti vogliono essere evitate, più un'azienda si distingue dal cliente con i tanti piccoli aiuti gratuiti. Scopri di più

Riabilitazione della mandibola mediante intervento di implantologia immediata e restauro immediato

Magazine PIP • Pratica implantare e protesi implantare • Agosto 2022 | Issue 4' Riabilitazione della mandibola mediante intervento di implantologia immediata e restauro immediato Catarina G. Rodrigues, DDS, MSc – Manuel D. Marques, DDS - Raquel Bandeira, CDT Il successo di qualsiasi trattamento odontoiatrico complesso dipende da una corretta diagnosi e dalla pianificazione del trattamento. La pianificazione digitale del trattamento, la pianificazione protesica a ritroso e la chirurgia iScopri di più

Alta qualità di impianti con sistema C-Tech.

Magazine PIP • Practical implantology and implant prosthetics • Novembre 2019 Alta qualità di impianti con sistema C-Tech. Full Smile, sotto la direzione di Lütfü Agic, proprietario di attività commerciali conosciuto nel mondo dell'implantologia, fornisce consigli a proposito di un assortimento di alta qualità di impianti con sistema C-Tech, materiali biologici come Bioteck e strumenti e dispositivi dentali e chirurgici di devemed. Come si impone una realtà così piccola in tempi di Scopri di più

Ricostruzione completa dell'arcata mediante chirurgia guidata e carico immediato. Studio clinico su 12 pazienti con 1 anno di follow-up

Henriette Lerner, Uli Hauschild, Robert Sader & Shahram Ghanaati Abstract - Introduzione La chirurgia implantare guidata è considerata una procedura sicura e minimamente invasiva senza lembo. Tuttavia, la chirurgia guidata senza lembo, il posizionamento dell'impianto negli alveoli post-estrattivi e il carico immediato di ricostruzioni fisse ad arcata completa senza gengiva artificiale non sono ancora valutati in modo approfondito. L'obiettivo del presente studio clinico retrospettivo eScopri di più

Prefooter ITA